A) running winding only
B) starting winding only
C) either (a) or (b)
D) both (a) and (b)
Correct Answer
verified
Multiple Choice
A) 100 uF
B) 200 uF
C) 300 uF
D) 400 uF
Correct Answer
verified
Multiple Choice
A) 10°
B) 30°
C) 60°
D) 90°
Correct Answer
verified
Multiple Choice
A) Capacitor start motor
B) Capacitor run motor
C) Split phase motor
D) Shaded pole motor
Correct Answer
verified
Multiple Choice
A) high resistance and low inductance
B) low resistance and high inductance
C) high resistance as well as high inductance
D) low resistance as well as low inductiance
Correct Answer
verified
Multiple Choice
A) a single turn of heavy wire which is in parallel with running winding
B) a single turn of heavy copper wire which is short-circuited and carries only induced current
C) a multilayer fine gauge copper wire in parallel with running winding
D) none of the above
Correct Answer
verified
Multiple Choice
A) is opposite to that of brush shift
B) is the same as that of brush shift
C) is independent of brush shift
D) none of the above
Correct Answer
verified
Multiple Choice
A) Split motor
B) Shaded-pole motor
C) Reluctance motor
D) None of these
Correct Answer
verified
Multiple Choice
A) Repulsion motor
B) Reluctance motor
C) Hysteresis motor
D) Universal motor
Correct Answer
verified
Multiple Choice
A) disconnects auxiliary winding of the motor
B) disconnects main winding of the motor
C) reconnects the main winding the motor
D) reconnects the auxiliary winding of the motor
Correct Answer
verified
Multiple Choice
A) short circuited capacitor
B) capacitor value hiving changed
C) open circuiting of capacitor
D) none of the above
Correct Answer
verified
Multiple Choice
A) improve power factor
B) increase overload capacity
C) reduce fluctuations in torque
D) to improve torque
Correct Answer
verified
Multiple Choice
A) Universal motor
B) Shaded pole type motor
C) Capacitor start motor
D) Capacitor start and run motor
Correct Answer
verified
Multiple Choice
A) Capacitor run motor
B) Shaded pole motor
C) Capacitor start motor
D) Split phase motor
Correct Answer
verified
Multiple Choice
A) 95% to 99%
B) 80% to 90%
C) 50% to 75%
D) 5% to 35%
Correct Answer
verified
Multiple Choice
A) the starting winding is connected through a centrifugal switch
B) the running winding is connected through a centrifugal switch
C) both starting and running windings are connected through a centrifugal switch
D) centrifugal switch is used to control supply voltage
Correct Answer
verified
Multiple Choice
A) inductor
B) capacitor
C) resistor
D) shading coils
Correct Answer
verified
Multiple Choice
A) more than i.he rated torque
B) rated torque
C) less than the rated torque
D) zero
Correct Answer
verified
Multiple Choice
A) repulsion induction motor
B) repulsion motor
C) repulsion start induction run motor
D) none of the above
Correct Answer
verified
Multiple Choice
A) run for about 1 minute
B) run for about 5 minutes
C) picked up about 50 to 70 per cent of rated speed
D) picked up about 10 to 25 per cent of rated speed
Correct Answer
verified
Showing 1 - 20 of 25