Filters
Question type

The differences in plugs and receptacles are based on the and voltage rating of the device.


A) resistance
B) conductance
C) geometry
D) ampacity

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

In commercial buildings, protection is required for all 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms, in kitchens, on rooftops, outdoors, within 6 ft (1.8 m) from the outside edge of any sink, in indoor wet locations, in locker rooms with adjacent shower facilities, and in garages, bays, and similar areas.


A) NEC
B) EWC
C) GFCI
D) HOT

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

How do you prevent neutral conductors from overheating?

Correct Answer

verifed

verified

A problem that occurs where there is a h...

View Answer

An acceptable impedance for the grounding path associated with normal equipment grounding for branch-circuit wiring is ohms.


A) 1 to 2
B) 3 to 4
C) 5 to 6
D) 7 to 8

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

When the wiring method is cable, you are stuck with the conductor insulation colors typically provided by the manufacturer.For three conductor cable, this will typically be black, white, and .


A) red
B) blue
C) green
D) orange

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

How common are double-pole switches, and where are they used?

Correct Answer

verifed

verified

A double-pole switch is rarely used on l...

View Answer

A switch is used where it is desired to control a light or group of lights, or other load, from one switching point.


A) three-way
B) single-pole
C) four-way
D) traveler

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

To reduce "electrical noise" (electromagnetic interference) , circuits with receptacle outlets that serve loads such as cash registers, computers, or other sensitive electronic equipment are often supplied by receptacles.


A) low-pass filtered
B) high-pass filtered
C) isolated ground
D) hospital-grade

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

The cover that is placed on a recessed box containing a receptacle or a switch is called a .


A) groundplate
B) faceplate
C) raised cover
D) double-pole

E) All of the above
F) C) and D)

Correct Answer

verifed

verified

What is the difference between the acceptable impedance of a ground path for branch-circuit wiring and the acceptable impedance for electronic equipment?

Correct Answer

verifed

verified

The acceptable impedance of the ground p...

View Answer

A 3-way switch has a common terminal to which the switch blade is always connected, and it has two other terminals called terminals.


A) mover
B) utility
C) traveler
D) mobile

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

C

An ac-dc general­use snap switch is always marked with the .


A) resistance
B) year of manufacture
C) phrase "ac­dc switch"
D) current and voltage rating

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

An ungrounded conductor is also known as a conductor.


A) hot
B) ground
C) neutral
D) positive

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

In locations where severe abuse or heavy use is expected, receptacles are recommended.


A) electronic equipment
B) hospital-grade
C) isolated ground
D) locking plug

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

B

When using cable for the wiring of 3-way switches, NEC 200.7(C) (1) permits the use of a conductor with insulation that is white or or has three continuous white stripes (not too common) as a switch supply only if the conductor is permanently reidentified by painting or other effective means.


A) black
B) red
C) green
D) gray

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

D

Quality voltage provides a clean wave that is free from distortion.


A) triangle
B) sine
C) square
D) sawtooth

E) A) and C)
F) None of the above

Correct Answer

verifed

verified

How are snap switches and metal faceplates grounded?

Correct Answer

verifed

verified

A metal box is considered adequately gro...

View Answer

Most electricians refer to switches as "toggle switches" or "wall switches."


A) snap
B) pressure
C) float
D) general

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

What is electrical noise, and what is its source?

Correct Answer

verifed

verified

"Electrical noise," as referred to when ...

View Answer

Isolated ground receptacles are required by NEC 406.2(D) to have a(n) triangle on their face.


A) orange
B) green
C) blue
D) red

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Showing 1 - 20 of 20

Related Exams

Show Answer